VOC Meter - Portable Handheld Monitor
Portable Handheld Monitor for Volatile Organic Compounds 0 - 15,000 parts pm by volume (mg/m3)
Description
In our experience monitoring the VOC's in a laboratory is one of the most underrated QC test that people conduct.
IVFSynergy find high levels of VOC's when we test facilities during servicing or fault finding in a range of equipment that initially really surprise our clients.
High concentrations of these are widely regarded as damaging for embryo development.
Specifications
- Portable Handheld VOC Monitor with three second response time.
- DS-1018-05 02/16 Sensor
- Gas Monitor Range Resolution Response Time T90 VOCs 0 to 999.9 ppm 1,000 to 15,000 ppm 0.1 ppm 1 ppm < 3 s < 3 s
- Weight 26 oz (738 g)
- Photoionization sensor with standard 10.6 eV or optional 9.8 eV or 11.7 eV lamp Rechargeable, external field-replaceable Lithium-Ion battery pack
- Running time 16 hours of operation (12 hours with alkaline battery adapter)
- VOCs as ppm by volume (mg/m3)
- Date, time, temperature Alarms 95dB at 12" (30 cm) buzzer and flashing red LED to indicate exceeded preset limits
- Datalogging Standard 6 months at one-minute intervals Calibration Two-point or three-point calibration for zero and span.
- Calibration memory for 8 calibration gases, alarm limits, span values and calibration dates Sampling Pump
- Internal, integrated flow rate at 500 cc/mn
- Sample from 100' (30m) horizontally or vertically Low Flow Alarm Auto pump shutoff at low-flow condition Communication & Data Download
- Download data and upload instrument set-up from PC through charging cradle or optional Bluetooth™
- Wireless data transmission through built-in RF modem Wireless Network Mesh
Portable Handheld Monitor for Volatile Organic Compounds 0 - 15,000 parts pm by volume (mg/m3)
In our experience monitoring the VOC's in a laboratory is one of the most underrated QC test that people conduct.
IVFSynergy find high levels of VOC's when we test facilities during servicing or fault finding in a range of equipment that initially really surprise our clients.
High concentrations of these are widely regarded as damaging for embryo development.
- Portable Handheld VOC Monitor with three second response time.
- DS-1018-05 02/16 Sensor
- Gas Monitor Range Resolution Response Time T90 VOCs 0 to 999.9 ppm 1,000 to 15,000 ppm 0.1 ppm 1 ppm < 3 s < 3 s
- Weight 26 oz (738 g)
- Photoionization sensor with standard 10.6 eV or optional 9.8 eV or 11.7 eV lamp Rechargeable, external field-replaceable Lithium-Ion battery pack
- Running time 16 hours of operation (12 hours with alkaline battery adapter)
- VOCs as ppm by volume (mg/m3)
- Date, time, temperature Alarms 95dB at 12" (30 cm) buzzer and flashing red LED to indicate exceeded preset limits
- Datalogging Standard 6 months at one-minute intervals Calibration Two-point or three-point calibration for zero and span.
- Calibration memory for 8 calibration gases, alarm limits, span values and calibration dates Sampling Pump
- Internal, integrated flow rate at 500 cc/mn
- Sample from 100' (30m) horizontally or vertically Low Flow Alarm Auto pump shutoff at low-flow condition Communication & Data Download
- Download data and upload instrument set-up from PC through charging cradle or optional Bluetooth™
- Wireless data transmission through built-in RF modem Wireless Network Mesh